Getting Started
The Avonic CON300-IP is a versatile PTZ camera controller that supports IP and serial protocols. Follow the steps below to ensure a successful installation and first-time use.
- Use the included power adapter only: Only use the supplied 12V/2.5A adapter (model GME60C-120400FDR).
- Connect the controller before powering on: Always connect camera(s) and network cables before switching the controller ON.
- Set IP address manually: The controller requires manual IP configuration via the menu before IP control is possible.
- Ensure same subnet: The controller and camera(s) must be on the same network subnet (e.g., 192.168.5.xxx).
- Assign camera channels: Cameras must be assigned to CH1–CH5 to enable control via buttons or joystick.
2. Unboxing and Power Setup
2.1 Unboxing
Be gentle with the moving parts especially with the joystick.
2.2 Powering On
Power the unit with the included 12V/2.5A adapter. Switch the physical power button to ON:
2.3 Connection Mode Selection
Use the NET button to toggle between IP and Serial (RS232) modes.
3. Connecting and Assigning Cameras
3.1 Serial Control
Default Visca Address: 1. Baud: 9600. Connect via supplied RJ45 to DIN-8 cable. Use CH1–CH5 for joystick control.
3.2 IP Control
- Connect via LAN switch.
- Assign IP: Menu > Ethernet > DHCP/Manual > Reboot.
- Add camera: Menu > Visca over IP > Add new > UDP, port 1259, IP address.
3.3 Channel Assignment
Use Menu > Visca over IP > Assign IP Channels. Each channel (CH1–CH5) must be unique.
If not assigned, default to broadcast: 255.255.255.255.
4. Operating the Controller
4.1 Startup
- Switch on controller.
- Press MENU for Ethernet/IP settings.
4.2 Navigation and Controls
- Joystick: Move = Pan/Tilt; Twist = Zoom; Press = HOME
- PTZ Speed: PTZ knob
4.3 Menu Navigation
- Access: MENU
- Navigate: Joystick
- Select: Push Joystick
5. Presets
Video: English, French, Spanish
5.1 Set
[SET] + [0–9] while in position. Preset 0 is default on boot.
5.2 Call
[0–9] directly. Supports presets set from web GUI or IR remote.
5.3 Delete
[RESET] + [0–9] to clear. Press [RESET] again to return.
6. Navigating Camera OSD
Press and hold MENU to activate OSD mode.
- TELE = Select
- WIDE = Back
- Left/Right = Change values
7. Ethernet Configuration
7.1 Manual Setup
MENU > Ethernet > DHCP OFF > Enter IP/Subnet/Gateway > Reboot
7.2 DHCP Setup
Enable DHCP, reboot controller.
8. Advanced Settings
8.1 Manual vs Auto Focus
Press Auto Focus button or turn Focus Knob.
8.2 Rocker Calibration
MENU > 6. Rocker > Zoom Rocker Calibration
8.3 Factory Reset
MENU > 11. Reset Device > Confirm
Alternate: TELE press > Joystick press > WIDE press > Joystick press
9. Troubleshooting and Maintenance
9.1 Common Issues
- No power? Check adapter/socket.
- No serial/IP control? Check cables, protocol, and settings.
9.2 Maintenance
- Unplug when unused.
- Clean dry or slightly damp cloth. No chemicals.
9.3 Reset Zoom Rocker
MENU > Rocker > Zoom Rocker Calibration